WEIGHING CONTROLLER FT-13 TTEECCHHNNIICCAALL MMAANNUUAALL For Firm
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 10 of 56 4.2.2 Standard Load Cell Connection The load cell wiring should be made carefully before
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 11 of 56 The electrical connection of the inputs and outputs should be made as shown in the Fig
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 12 of 56 5. FRONT PANEL AND KEYPAD 5.1 Weight Display and Status LEDs Figure 5.1 Front panel
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 13 of 56 5.2 Keypad The meaning of the front panel keys and the key functions are: Key Meaning
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 14 of 56 6. SETUP AND CALIBRATION 6.1 Basics 6.1.1 Basic Setup Keys on the Frontplate The symbol
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 15 of 56 6.3 Configuration Parameters [1--] Configuration Block [12-] Filter In this block the
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 16 of 56 6.5 Scale Calibration [3--] Calibration Block The calibration of the scale will be per
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 17 of 56 7. FILLING WITH FT-13 7.1 Overview FT-13 has 9 standard filling programmes for common f
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 18 of 56 7.3 Filling Programmes 7.3.1 Programme 0: Open Container Filling FT-13FT-13 Application
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 19 of 56 7.3.2 Programme 1: Bunghole Container Filling FT-13FT-13 Application: Container with b
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 2 of 56 Table of Contents: 1. Safety Instructions ...
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 20 of 56 Process Messages Description This message is shown on the display during the start dela
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 21 of 56 Condition: Safety > tare max. If the filling valve doesn‟t go through the hole of
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 22 of 56 Process Parameters Description + + + When FT-13 is in the “Ready” status
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 23 of 56 7.3.5 Programme 4: Filling and Discharging FT-13DIS C HAR G EFT-13FT-13DischargeFT-13FT-
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 24 of 56 7.3.6 Programme 5: Charging and Discharging FT-13FT-13 Application: Weigh-in / Weigh-o
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 25 of 56 7.3.7 Programme 6: Filling and Emptying Type 2 FT-13FT-13 Application: Bagging machine
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 26 of 56 Process Messages Description It is displayed during automatic zeroing. It is displaye
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 27 of 56 At the end of the filling cycle the filling machine waits for the d_End delay time to r
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 28 of 56 Process parameters Description + + + When type FT-13 is in the “Ready” sta
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 29 of 56 7.4 Target and Preset Entry TARGET and TOLERANCE ENTRY + Press F and N keys seque
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 3 of 56 8. Communication...
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 30 of 56 7.5 Recipe Memory A recipe is a set of parameters for different materials and/or differ
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 31 of 56 7.6 Setup [5--] Filling Block [50-] + [51-] Filling Parameters In this section the pro
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 32 of 56 [508 ] Maximum filling time [ XXXXXX ] This parameter controls the filling / discha
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 33 of 56 7.7 Error Messages Error Message Description The “Tare range” error message appears if
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 34 of 56 8. COMMUNICATION 8.1 Overview about Communication Application Hardware-Channel Interfac
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 35 of 56 The RS485 interface termination can be done by short circuiting pin no. 19 and 20 (panel
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 36 of 56 Start : Start time of the first filling / discharging cycle End : End time of the las
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 37 of 56 [023 XX] Address You can define a device address between 1 and 99 by this parameter. En
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 38 of 56 8.3.2 Setup There are several setup parameters for the Ethernet network as described bel
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 39 of 56 Frequently Asked Questions (FAQ) Question: The Ether X could not reach the FT-1x instru
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 4 of 56 RIGHTS AND LIABILITIES All rights reserved. No part of this publication may be reproduc
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 40 of 56 8.4 Profibus Option Indicators which are equipped with the Profibus option can be conne
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 41 of 56 8.6 ProfiNet Option Indicators which are equipped with the ProfiNet option can be conne
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 42 of 56 8.7 CANopen Option Indicators which are equipped with the CANopen option can be connect
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 43 of 56 9. DIAGNOSTICS The parameter block [9--] contains certain functions for checking and tes
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 44 of 56 APPENDIX 1: SETUP AND CALIBRATION MENU FT-13 Setup and Calibration Menu 509MAX WEIGHTE
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 45 of 56 APPENDIX 2: CONTINUES OUTPUT MODE DATA STRUCTURE The format and the definition of the c
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 46 of 56 APPENDIX 3: MODBUS RTU DATA STRUCTURE If the instrument is programmed for Modbus, it ca
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 47 of 56 Write command Modbus register Function code Register address No. of registers Data byte
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 48 of 56 Modbus exception codes 1 : Function code is not supported 2 : Address is out of rang
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 49 of 56 APPENDIX 4: PROFIBUS DP / PROFINET DATA STRUCTURE The output from FT-13 on PLC requests
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 5 of 56 2. DECLARATION OF CONFORMITY
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 50 of 56 Any input to FT-13 is in four words and according to the table below. FT-13 Input Bit no
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 51 of 56 APPENDIX 5: CANOPEN DATA STRUCTURE The output from FT-13 on PLC requests is in two doub
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 52 of 56 7...0 Calibration status 0000 0001 Ready for calibration 0000 0011 Zero calibration in p
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 53 of 56 APPENDIX 6: ERROR TABLE The FT-13 Weighing Controller has been designed as very reliabl
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 54 of 56 APPENDIX 7: PARAMETER’S DEFAULT TABLE Parameter Factory defaults 0-- Interface 00- Se
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 55 of 56
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 56 of 56 www.flintec.com
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 6 of 56 3. OVERVIEW The FT-13 Weighing Controller is an economic and powerful state-of-the-art in
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 7 of 56 3.3 Technical Specifications Accuracy Accuracy class: III EU Type approved: 10 000 inter
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 8 of 56 3.4 Housing Dimensions 3.4.1 Stainless Steel Housing 70220160230701001570220160230220160
FT-13 Technical Manual, Rev. 1.40 March 2013 Page 9 of 56 4. INSTALLATION AND COMMISSIONING PRECAUTION: Please read this manual carefully before en
Comments to this Manuals