Analog Amplifier FAA-27 Technical Manual Flintec GmbH Bemannsbruch 9 74909 Meckesheim GERMANY www.flintec.com
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 9 of 21 Pin Name Definition I Current Output V Voltage Output G GND Shield Current out
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 10 of 21 You can also set the analog output type after power on as; Turn the programming swi
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 11 of 21 5. Adjustments 5.1 Adjustment with Rotary Switches To start the adjustment the progra
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 12 of 21 Use the formula for calculating the analog output value Analog Output = Minimum outpu
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 13 of 21 5.2 Fast Adjustment To Nominal Output Range You may perform fast adjustment method if
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 14 of 21 5.4 Adjustment (eCal) With PLC All instruments are adjusted in the production to opera
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 15 of 21 2. eCal procedure steps: Descriptions Step 1 START eCal Command: @0110
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 16 of 21 4. Load Factory Defaults: Descriptions Command: @011000240001025AA5C9
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 17 of 21 6. Setpoints 6.1 Setpoint Connection FAA-27 has 2 free relay contact output. These ou
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 18 of 21 7. Operation There are 3 LEDs and 2 rotary switches on the front panel of FAA-27. The
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 1 of 21 Table of Contents 1. Safety Instructions ...
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 19 of 21 8. Programming With xFace Software Over RS232 FAA-27 has RS232C serial interface to pe
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 20 of 21 4. Select the analog output type. 5. Enter Total Load Cell capacity, Average Load Ce
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 21 of 21 9. Trouble Shooting The type FAA-27 amplifier is designed as a very reliable and virtu
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 2 of 21 RIGHTS AND LIABILITIES 1. Safety Instructions CAUTION READ this manual BEFORE operat
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 3 of 21 2. Declaration of Conformity
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 4 of 21 3. Front View, Features and Specifications Microcontroller based analog load cell tran
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 5 of 21 Meanings of the positions of rotary switches; Programming (Prog) switch V Voltage outpu
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 6 of 21 TECHNICAL SPECIFICATIONS Analogue input range 0 mV to 20 mV Min. input range < 1 mV
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 7 of 21 4. Installation and Commissioning Recommendations Warning: Please care the following w
FAA-27, Technical Manual, Rev. 1.1, June 2014 Page 8 of 21 4.1 Mechanical Installation The place where you will use/install your instrument shoul
Comments to this Manuals